Vessel
Capacity m³: 6.4
Material: S31603+Q345R
Design pressure MPa: 6.4
Design temperature ºC: 230
Work pressure MPa: 5.0
Work temperature ºC: 200
Medium: Hydrogen, catalyst
Working life: 10 years
Jacket
Volumn m³: 0.6
Material: Q245R
Design pressure MPa: 0.7
Design temperature ºC: 170
Work pressure MPa: 0.6
Work temperature ºC: 20-165
Medium: steam/ cooling water
Heat exchange area m2: 11.9
Coil tube
Volumn m³: 0.09
Material: S31603
Design pressure MPa: 0.6
Design temperature ºC: 230
Work pressure MPa: 0.5
Work temperature ºC: 200
Medium: heat-transfer oil
Heat exchange area m2: 10.4
Total weight Kg: 8202
For confidential reason, the drawing is in low definition. Please contact us for more information.
MODEL |
FCHA1000-2000L |
FCHA3000-5000L |
FCHA6000-8000L |
FCHA10000-15000L |
FCHA15000-25000L |
CAPACITY |
1000-2000L |
3000-5000L |
6000-8000L |
10000-1 5000L |
15000-25000L |
WORK PRESSURE MPa |
-0.1-10.0 |
-0.1-10.0 |
-0.1-10.0 |
-0.1-10.0 |
-0.1 -8.0 |
WORK TEMPERATURE C° |
-15-320 |
-15-320 |
-15-320 |
-15-320 |
-15-320 |
rpm |
0-320 |
0-320 |
0-320 |
0-320 |
0-320 |
DC motor power W |
3.0-11.0 |
11.0-22.0 |
15-37.0 |
22.0-55.0 |
37.0-75.0 |
Main materials |
09MnNiDR/16MnDR (low-temperature steel), 15CrMoR (high-temperature steel), stainless steel S30408/S32168/S31603, S39042, titanium material, duplex steel, shackle material, Hastelloy alloy, zirconium material, Monel, and other materials used for explosive composite plates. |
Heating form |
Jacket thermal oil, jacket steam, outer half pipe, inner coil pipe; Electric heating/flue gas heating (435ºC). |
Mixing form |
Disc turbine type, asymmetric turbine type, three blade impeller type, disc inclined blade, four wide blade, propulsion type, impeller type, anchor type, frame type, screw belt type, etc. |
Shaft sealing form |
Magnetic coupling drive with static sealing, zero leakage, long service life, simple installation, safe and environmentally friendly. |
Remarks |
Other special requirements, touch screen intelligent control, program control, and connection to DCS systems shall be designed, manufactured, and configured according to user needs. |
LUHAO Chemical Machinery Co. Ltd |
|
|
|
|
|
|
Pressure Vessel Design Information Collection Table |
|
|
Vessel |
Jacket (Coil) |
Work Medium |
Name |
|
|
Components |
|
|
Density (Kg/m³) |
|
|
Characteristics |
|
|
Viscosity (cP) |
|
|
Flow Velocity(m³/h) |
|
|
Design pressure (Mpa) |
|
|
Work pressure (Mpa) |
|
|
Design temperature(ºC) |
|
|
Work temperature (ºC) |
|
|
Wall temperature (ºC) |
|
|
Diamter (mm) |
|
|
Length (mm) |
|
|
Capacity(m³) |
|
|
Effective capacity (m³) |
|
|
Corrosion allowance (mm) |
|
|
Corrosion speed (mm/year) |
|
|
Recommended Materials |
|
|
Lowest value of average monthly temperature(ºC) |
|
Site location |
|
Installation condition |
Indoor or Outdoor |
|
|
|
|
|
|
Catalyst Volume(m³) |
|
|
|
Catalyst Density(Kg/m³) |
|
|
|
Heat Transfer Area(m2) |
|
|
|
Coil Specification |
|
|
|
Basic Wind Pressure(Mpa) |
|
|
|
Seismic Basic Intensity |
|
|
|
Ambient Temperature(ºC) |
|
|
|
Site Type |
|
|
|
Operating Mode |
|
|
|
Insulation Materials |
Name |
|
|
|
Thickness |
|
|
|
Density (Kg/m³) |
|
|
|
Seal Requirements |
|
|
|
Liquid Level Gauge |
|
|
|
Emergency Cut-off |
|
|
|
Static Electricity Removal |
|
|
|
Anti Eddy Current Requirement for Liquid Outlet |
|
|
|
Installation and Mantainance Requirements |
|
|
|
Expected Useful Life (years) |
|
|
|
|
|
|
|
|
|
Safety accessories |
|
Vessel |
Jacket (Coil) |
Location |
|
|
Type |
|
|
Specification |
|
|
Quantity |
|
|
Set pressure(Mpa) |
|
|
Burst disc |
|
|
Burst pressure(Mpa) |
|
|
Safety discharge(kg/h) |
|
|
|
|
|
|
|
|
Agitator |
Type |
|
|
|
Impeller Diameter(mm) |
|
|
|
Speed(r/min) |
|
|
|
Motor |
Model |
|
|
|
Power(kw) |
|
|
|
Explosion Proof Grade |
|
|
|
Speed reducer |
|
|
|
Kindly fill this form for us to give a quote for you.Kindly fill this form for us to give a quote for you.